A lad-used servo permanent magnet synchronous motor has been accidentally damaged due to overcurrent. On the one hand, the mechanical damage, in the end, bearing and break part generates acoustic noise even when rotating the shaft by hand. On the other hand, the back electromotive force of the motor becomes unbalanced and exceedingly high...
-
2020 (v1)PublicationUploaded on: April 14, 2023
-
2017 (v1)Publication
The study presents the direct flux and current vector control of an induction motor (IM) drive, which is a relatively newer and promising control strategy, through the use of model predictive control (MPC) techniques. The results highlight that the fast flux control nature of direct flux control strategy is further enhanced by MPC. Predictive...