The aim of this split-mouth, double-blind, randomized study was to determine whether pulsed electromagnetic field therapy (PEMF) can improve swelling and the management of pain after full-arch immediate loading implant surgery. Eleven patients were selected for the study. Each patient received four distal tilted implants in the upper or lower...
-
2016 (v1)PublicationUploaded on: April 14, 2023
-
2016 (v1)Publication
Objective: The aim of this study was to evaluate the accuracy of 7 different implant impression techniques for full-arch prostheses. Materials and Methods: A master cast simulating an edentulous arch with 4 implants was used. Seven impression techniques were tested: open tray with polyether Impregum (OTI); open tray with splint-polyether...
Uploaded on: March 27, 2023 -
2016 (v1)Publication
La riabilitazione di arcate edentule o a dentatura gravemente compromessa mediante l'implantologia a carico immediato si è dimostrata nel corso degli ultimi decenni una procedura affidabile e predicibile. Il presupposto cardine per il successo clinico risiede nella rigorosa osservanza di opportuni accorgimenti che consentano di promuovere...
Uploaded on: April 14, 2023 -
2015 (v1)Publication
Scopo di questa ricerca è stato valutare la biocompatibilità e le caratteristiche meccaniche di framework in materiale composito rinforzato con fibra di carbonio per protesi fisse su impianti
Uploaded on: April 14, 2023 -
2015 (v1)Publication
PURPOSE: The aim of this study was to analyze through a three-dimensional finite element analysis (3D-FEA) stress distribution on four implants supporting a full-arch implant-supported fixed prosthesis (FFP) using different prosthesis designs. MATERIALS AND METHODS: A 3D edentulous maxillary model was created and four implants were virtually...
Uploaded on: April 14, 2023 -
2014 (v1)Publication
No description
Uploaded on: April 14, 2023 -
2014 (v1)Publication
This prospective study reports the 6-year outcomes for patients rehabilitated with an immediate loading protocol of the maxilla (Columbus Bridge Protocol). In this study, 164 implants were inserted in 37 patients and loaded within 24 to 36 hours. Four implants failed during the first 6 months. At the 6-year follow-up, a mean bone loss of 1.52...
Uploaded on: April 14, 2023 -
2017 (v1)Publication
Objectives: The aimof the present study was to investigate the biocompatibility and mechanical characteristics of dental implant frameworks made of carbon fiber composite. Methods: The biocompatibility of intact samples and fragments was evaluated by cell count and MTT test according to EN-ISO 10993-5:2009 directions. Destructive and...
Uploaded on: April 14, 2023 -
2016 (v1)Publication
Several factors contribute to distortion of implant prostheses during fabrication and could prevent passive, accurate adaptation between implants and implant frameworks. The misfit between implants and restorative components may be significant and possibly lead to biologic or mechanical complications. The aim of this article is to describe a...
Uploaded on: March 27, 2023