Detecting the primordial 'B-mode' polarization of the cosmic microwave background is one of the major challenges of modern observational cosmology. Microwave telescopes need sensitive cryogenic bolometers with an overall equivalent noise temperature in the nK range. In this paper, we present the development status of large area (about 1 cm2)...
-
2016 (v1)PublicationUploaded on: April 14, 2023
-
2016 (v1)Publication
In the last years organic scintillators have been largely investigated in order to achieve high light yield together with good time response. Pure organic compound with high quality crystalline structure can achieve both this goals. Among a large type of organic compound, para-terphenyl (C18H14) have proven to have practical applications as...
Uploaded on: April 14, 2023 -
2017 (v1)Publication
A new timing detector has been developed to measure ∼50 MeV/c positrons with a time resolution of σt≃30ps in the MEG II experiment. The detector are segmented into 512 scintillation counters, each of which consists of 120×(40or50)×5mm3 size BC-422 and two arrays of six AdvanSiD silicon photomultipliers. The single-counter resolutions are...
Uploaded on: March 27, 2023 -
2015 (v1)Publication
The MEG experiment is now being upgraded to search for the charged lepton flavor violating decay μ+ → e+γ with an improved branching ratio sensitivity, 5 × 10-14. We are developing a new Timing Counter to precisely measure the timing of the decay positrons under the high rate environment. The Timing Counter consists of 512 counters and each...
Uploaded on: April 14, 2023 -
2015 (v1)Publication
The development of a Timing Counter detector with a resolution in the range of ≈ 30 ps will be presented. The detector was designed for the upgrade of the MEG II experiment looking for the μ+→ e+γ decay with an improved sensitivity of one order of magnitude with respect to the previous MEG setup. In this paper the design of the TC single pixel...
Uploaded on: April 14, 2023 -
2016 (v1)Publication
The HOLMES experiment will provide an important step forward in direct neutrino mass measurements with a calorimetric approach as an alternative to spectrometry. HOLMES will perform a calorimetric measurement of the energy released in the decay of163Ho and will deploy a large array of transition-edge sensor microcalorimeters with implanted163Ho...
Uploaded on: March 27, 2023 -
2016 (v1)Publication
The development of a Timing Counter detector designed for the MEGII upgrade of the MEG experiment, which strives to improve the sensitivity on theμ+→e+γ decay of an order of magnitude, is presented. It is based on two sets of counters (sectors) arranged on a semi-cylindrical structure; each sector consists of 256 counters. Each counter consists...
Uploaded on: April 14, 2023 -
2016 (v1)Publication
The MEGII Timing Counter will measure the positron time of arrival with a resolution of ~ 30 ps relying on two arrays of scintillator pixels read out by 6144 Silicon Photomultipliers (SiPMs) from AdvanSiD. They are characterised, measuring their breakdown voltage, to assure that the gains of the SiPMs of each pixel are as uniform as possible,...
Uploaded on: April 14, 2023