Introducción: La planificación radioterápica más precisa es la basada en un cálculo del transporte explícito del haz de partículas, desde su generación en la cabeza del acelerador lineal, y en su interacción con los modificadores y colimadores, hasta la deposición de su energía en los tejidos del paciente con densidades heterogéneas. No...
-
July 13, 2015 (v1)PublicationUploaded on: March 27, 2023
-
April 29, 2020 (v1)Publication
A model based on a specific phantom, called QuAArC, has been designed for the evaluation of planning and verification systems of complex radiotherapy treatments, such as volumetric modulated arc therapy (VMAT). This model uses the high accuracy provided by the Monte Carlo (MC) simulation of log files and allows the experimental feedback from...
Uploaded on: March 26, 2023 -
February 8, 2024 (v1)Publication
Purpose: We present a hybrid direct MLC aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo 30 treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical...
Uploaded on: February 11, 2024 -
February 8, 2024 (v1)Publication
Purpose: To report the clinical implementation of a novel external beam radiotherapy technique for accelerated partial breast irradiation treatments based on combined electron and photon modulated beams radiotherapy (MERT+IMRT) with conventional MLC. Materials and methods: A group of patients was selected to test the viability of the...
Uploaded on: February 11, 2024 -
June 8, 2022 (v1)Publication
The purpose of this work is to present useful recommendations for the use of [18F]FDG-PET/CT imaging in radiotherapy planning and monitoring under different versions of EARL accreditation for harmonization of PET devices. A proof-of-concept experiment designed on an anthropomorphic phantom was carried out to establish the most suitable...
Uploaded on: March 25, 2023 -
February 8, 2024 (v1)Publication
Purpose To develop a new optimization algorithm to carry out true dose painting by numbers (DPBN) planning based on full Monte Carlo (MC) calculation. Methods Four configurations with different clustering of the voxel values from PET data were proposed. An optimization method at the voxel level under Lineal Programming (LP) formulation was used...
Uploaded on: February 11, 2024 -
March 4, 2019 (v1)Publication
In this work we present a methodology able to use harmonized PET/CT imaging in dose painting by number (DPBN) approach by means of a robust and accurate treatment planning system. Image processing and treatment planning were performed by using a Matlab-based platform, called CARMEN, in which a full Monte Carlo simulation is included. Linear...
Uploaded on: December 5, 2022