Published January 2012 | Version v1
Journal article

The role of clips in preventing migration of fully covered metallic esophageal stents: a pilot comparative study.

Others:
Endoscopie Digestive ; Hôpital Archet 2 [Nice] (CHU)
Hépato-Gastroentérologie ; Centre Hospitalier Universitaire de Nice (CHU Nice)
Immunite anti-tumorale et chimiotactisme. Adenocarcinomes et métastases ; Université Nice Sophia Antipolis (1965 - 2019) (UNS) ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-IFR50-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Côte d'Azur (UCA)
Infection bactérienne, inflammation, et carcinogenèse digestive ; Université Nice Sophia Antipolis (1965 - 2019) (UNS) ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-IFR50-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Côte d'Azur (UCA)
Centre méditerranéen de médecine moléculaire (C3M) ; Université Nice Sophia Antipolis (1965 - 2019) (UNS) ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Côte d'Azur (UCA)
Institut de Biologie Valrose (IBV) ; Université Nice Sophia Antipolis (1965 - 2019) (UNS) ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)-Université Côte d'Azur (UCA)
Groupe de Recherche Angevin en Economie et Management (GRANEM) ; Université d'Angers (UA)-AGROCAMPUS OUEST-Institut National de l'Horticulture et du Paysage
Centre Hospitalier Universitaire de Nice ; Centre Hospitalier Universitaire de Nice (CHU Nice)
Institut de l'information scientifique et technique (INIST) ; Centre National de la Recherche Scientifique (CNRS)
Service de Chirurgie thoracique ; Centre Hospitalier Universitaire de Nice (CHU Nice)
Service de Chirurgie Digestive / Centre de Transplantation Hépatique [CHU Nice] ; Centre Hospitalier Universitaire de Nice (CHU Nice)
Université Nice Sophia Antipolis (1965 - 2019) (UNS) ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)

Description

BACKGROUND: Migration is the most common complication of the fully covered metallic self-expanding esophageal stent (SEMS). This study aimed to determine the potential preventive effect of proximal fixation on the mucosa by clips for patients treated with fully covered SEMS. METHODS: In this study, 44 patients (25 males, 57%) were treated with fully covered SEMS including 22 patients with esophageal stricture (4 malignant obstructions, 6 anastomotic strictures, and 12 peptic strictures) and 22 patients with fistulas or perforations (10 anastomotic leaks, 4 perforations, and 8 postbariatric surgery fistulas). The Hanarostent (n = 25), Bonastent (n = 5), Niti-S (n = 12), and HV-stent (n = 2) with diameters of 18 to 22 mm and lengths of 80 to 170 mm were used. Two to four clips (mean, 2.35 ± 0.75 clips) were used consecutively in 23 patients to fix the upper flared end of the stent with the esophageal mucosal layer. Stent migration and its consequences were collected in the follow-up assessment with statistical analysis to compare the patients with and without clip placement. RESULTS: No complication with clip placement was observed, and the retrieval of the stent was not unsettled by the persistence of at least one clip (12 cases). Stent migration was noted in 15 patients (34%) but in only in 3 of the 23 patients with clips (13%). The number of patients treated to prevent one stent migration was 2.23. The predictive positive value of nonmigration after placement of the clip was 87%. In the multivariate analysis, the fixation with clips was the unique independent factor for the prevention of stent migration (odds ratio, 2.3; 95% confidence interval, 0.10-0.01; p = 0.03). CONCLUSIONS: Anchoring of the upper flare of the fully covered SEMS with the endoscopic clip is feasible and significantly reduces stent migration.

Abstract

International audience