Published June 23, 2014 | Version v1
Conference paper

Calibration of the TWSTFT link between OCA and OP using a GPS link calibration

Description

Three independent time transfer techniques are in use in Observatoire de la Côte d'Azur (OCA): GPS, TWSTFT and T2L2. In Autumn 2013, a GPS receiver relative calibration campaign has been carried out. The result of this campaign, primary intended to compare GPS with T2L2, have allowed the calibration of the TWSTFT link between OCA and OP. We computed for OCA the value of CALR = -7111.9 ns, with an uncertainty U= 2.8 ns at k=2. From this calibration we caracterise the others links with the triangle closure technique.

Abstract

International audience

Additional details

Identifiers

URL
https://hal.archives-ouvertes.fr/hal-03734139
URN
urn:oai:HAL:hal-03734139v1

Origin repository

Origin repository
UNICA