External validation of Modified Breast Graded Prognostic Assessment for breast cancer patients with brain metastases: A multicentric European experience
- Others:
- Département d'oncologie Médicale ; CRLCC Val d'Aurelle - Paul Lamarque
- Institut de Recherche en Cancérologie de Montpellier (IRCM - U1194 Inserm - UM) ; CRLCC Val d'Aurelle - Paul Lamarque-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université de Montpellier (UM)
- Centre de Lutte contre le Cancer Antoine Lacassagne [Nice] (UNICANCER/CAL) ; UNICANCER-Université Côte d'Azur (UCA)
- Centre Azuréen de Cancérologie [Mougins, France]
Description
BACKGROUND:Several prognostic scores have been developed to estimate survival of breast cancer (BC) patients with brain metastases (BM). Modified Breast Graded Prognostic Assessment (GPA), based on a single-institution cohort of 1552 patients, has been proposed as refinement of Breast-GPA. In addition to age, tumour subtype and KPS, Modified Breast-GPA comprises number of BM. This study was designed to validate Modified Breast-GPA.PATIENTS AND METHODS:Clinical data of 668 BC patients diagnosed with BM at four institutions between 1996 and 2016 were reviewed. Patients were classified by Breast-GPA and Modified Breast-GPA. Overall survival (OS) was calculated from time of BM diagnosis to death or last follow-up. Cox proportional models were used to calculate hazard-ratios and their 95% CI. The performances of Breast-GPA and Modified Breast-GPA were compared using Harrell's concordance index.RESULTS:Median age at BM diagnosis was 56 years (range 24-85). At last follow-up, 632 patients (94.6%) had died. Median OS was 8.1 months (95% CI 6.9-9.4). The number of BM (1-3 vs. >3) was significantly associated with OS in univariate analysis (p < 0.001) and having >3 BM was identified as a negative prognostic factor in multivariate analysis. Both Breast-GPA and Modified Breast-GPA accurately predicted OS (p < 0.001 for both scores). Performance of Modified Breast-GPA was better: concordance indices were 0.6390 (95% CI, 0.6381 to 0.6399) and 0.6647 (95% CI, 0.6639 to 0.6655) for Breast-GPA and Modified Breast-GPA, respectively (p < 0.001).CONCLUSIONS:This work provides the first external independent validation of Modified Breast-GPA and confirms its better performance as compared to Breast-GPA.
Abstract
International audience
Additional details
- URL
- https://hal.umontpellier.fr/hal-02286072
- URN
- urn:oai:HAL:hal-02286072v1
- Origin repository
- UNICA