Performance and Clinical Impact of Radiomics and 3D-CNN Models for the Diagnosis of Neurodegenerative Parkinsonian Syndromes on 18F-FDOPA PET
- Others:
- Institut de Biologie Valrose (IBV) ; Université Nice Sophia Antipolis (1965 - 2019) (UNS)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)-Université Côte d'Azur (UniCA)
- Centre de Lutte contre le Cancer Antoine Lacassagne [Nice] (UNICANCER/CAL) ; UNICANCER-Université Côte d'Azur (UniCA)
- Département de Médecine Nucléaire [Nice] (CHU-Nice) ; Centre de Lutte contre le Cancer Antoine Lacassagne [Nice] (UNICANCER/CAL) ; UNICANCER-Université Côte d'Azur (UniCA)-UNICANCER-Université Côte d'Azur (UniCA)-Centre Hospitalier Universitaire de Nice (CHU Nice)
- Laboratoire d'Imagerie Translationnelle en Oncologie (LITO ) ; Institut Curie [Paris]-Institut National de la Santé et de la Recherche Médicale (INSERM)
Description
Purpose: The aim of this study was to compare the performance and added clinical value of a semiautomated radiomics model and an automated 3dimensinal convolutional neural network (3D-CNN) model for diagnosing neurodegenerative parkinsonian syndromes on 18 F-FDOPA PET images. Patients and Methods: This 2-center retrospective study included 687 patients with motor symptoms consistent with parkinsonian syndrome. All patients underwent 18 F-FDOPA brain PET scans, acquired on 3 PET systems from 2 different hospitals, and classified as pathological or nonpathological (by an expert nuclear physician). Artificial intelligence models were trained to replicate this medical expert's classification using 2 pipelines. The radiomics pipeline was semiautomated and involved manually segmenting the bilateral caudate and putamen nuclei; 43 radiomic features were extracted and combined using the support vector machine method. The deep learning pipeline was fully automatic and used a 3D-CNN model. Both models were trained on 417 patients and tested on an internal (n = 100) and an external (n = 170) test set. The final models' performance was evaluated using balanced accuracy and compared with that of a junior medical expert and nonexpert nuclear physician. Results: On the internal test set, the 3D-CNN model outperformed the radiomic model with a balanced accuracy of 99% (vs 96%). It led to diagnostic performance similar to that of a junior medical expert (only 1 in 100 patients misclassified by both). On the external test set from a less experienced hospital, the 3D-CNN model allowed physicians to correctly reclassify the diagnosis of 10 out 170 patients (6%). Conclusions: The developed 3D-CNN model can automatically diagnose neurodegenerative parkinsonian syndromes, also reducing diagnostic errors by 6% in less-experienced hospitals.
Abstract
International audience
Additional details
- URL
- https://hal.science/hal-04682405
- URN
- urn:oai:HAL:hal-04682405v1
- Origin repository
- UNICA