Published October 8, 2012
| Version v1
Conference paper
A Two-mode Interference Measurement for Nanometer Accuracy Absolute Distance Ranging
Contributors
Others:
- Astrophysique Relativiste Théories Expériences Métrologie Instrumentation Signaux (ARTEMIS) ; Université Nice Sophia Antipolis (1965 - 2019) (UNS) ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Institut national des sciences de l'Univers (INSU - CNRS)-Observatoire de la Côte d'Azur ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Université Côte d'Azur (UCA)-Université Côte d'Azur (UCA)-Centre National de la Recherche Scientifique (CNRS)
- CEDRIC. Traitement du signal et architectures électroniques (CEDRIC - LAETITIA) ; Centre d'études et de recherche en informatique et communications (CEDRIC) ; Ecole Nationale Supérieure d'Informatique pour l'Industrie et l'Entreprise (ENSIIE)-Conservatoire National des Arts et Métiers [CNAM] (CNAM) ; HESAM Université - Communauté d'universités et d'établissements Hautes écoles Sorbonne Arts et métiers université (HESAM)-HESAM Université - Communauté d'universités et d'établissements Hautes écoles Sorbonne Arts et métiers université (HESAM)-Ecole Nationale Supérieure d'Informatique pour l'Industrie et l'Entreprise (ENSIIE)-Conservatoire National des Arts et Métiers [CNAM] (CNAM) ; HESAM Université - Communauté d'universités et d'établissements Hautes écoles Sorbonne Arts et métiers université (HESAM)-HESAM Université - Communauté d'universités et d'établissements Hautes écoles Sorbonne Arts et métiers université (HESAM)
- ANR; CNES;
- Iliade
Description
We present a laser ranging system, under development, that uses a high frequency modulated beam to achieve sub-nm resolution by the combined use of interferometric and time-of-flight measurements. We first describe how the absolute distance is extracted from a two-mode interference signal. In particular we show that the signal, which presents both optical and synthetic wavelength scales, is essential to achieve nm-scale accuracy, despite the significant long-term phase drifts in the 20 GHz detection chains. Then we present results obtained with the telemeter implemented on an optical table, for a distance of about four meters, implemented by folding the laser beam path to the target. The challenge here is to achieve a phase and amplitude measurement of two 20 GHz signals with a resolution well below 10-4 cycle and 10-4, respectively, despite the fact that the signal undergoes very strong (×3 ) amplitude changes.
Abstract
International audienceAdditional details
Identifiers
- URL
- https://hal.archives-ouvertes.fr/hal-00914565
- URN
- urn:oai:HAL:hal-00914565v1
Origin repository
- Origin repository
- UNICA