- Astrophysique Relativiste Théories Expériences Métrologie Instrumentation Signaux (ARTEMIS) ; Université Nice Sophia Antipolis (1965 - 2019) (UNS) ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Institut national des sciences de l'Univers (INSU - CNRS)-Observatoire de la Côte d'Azur ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Université Côte d'Azur (UCA)-Université Côte d'Azur (UCA)-Centre National de la Recherche Scientifique (CNRS)
- CNES
- T2M
Description
We present a simple two-mode telemetry procedure which eliminates cyclic errors, to allow accurate absolute distance measurements. We show that phase drifts and cyclic errors are suppressed using a fast polarization switch that exchanges the roles of the reference and measurement paths. Preliminary measurements obtained using this novel design show a measurement stability better than 1 micron. Sources of residual noise and systematic errors are identified, and we expect that an improved but still simple version of the apparatus will allow accuracies in the nanometre range for absolute measurements of kilometre-scale distances.