Published 2017
| Version v1
Publication
Heat Extraction Distributed Thermal Response Test: A Methodological Approach and In-situ Experiment
Creators
Contributors
Description
The Thermal Response Test (TRT) is a worldwide adopted in-situ methodology able to estimate the ground thermal conductivity and borehole thermal
resistance. During the test the carrier-fluid exchanges a constant heat flux with the ground while circulating in a pilot Borehole Heat Exchanger (BHE).
During a Distributed Thermal Response Test (DTRT) the ground thermal conductivity and borehole thermal resistance are determined at different vertical
sections along the borehole.
The measured fluid temperature values are analysed with numerical or analytical approaches based on mathematical models which typically approximate
the BHE. Those models are based on some strict assumptions, including pure conduction and constant heat transfer rate.
During a heat extraction TRT the operating conditions to the ground are similar to the "winter mode" conditions of a working BHE system. In such case
the estimated thermal behaviour of the borehole can differ from the result obtained by means of a heat injection TRT. This issue is of peculiar interest for
water-filled boreholes, where the BHE thermal resistance is related to the water temperature and density gradient in the borehole filling-space. In this
operating mode a heat pump is usually employed and the constant heat transfer rate condition required by the models can be difficult to be respected since
the efficiency of the cooling-machine is dependent on the inlet carrier-fluid temperature to the evaporator.
In this paper a methodology to perform a heat extraction DTRT with constant heat transfer rate to the ground is presented. The approach described has
been applied in a real water-filled borehole installed in Stockholm, Sweden. Data analysis results are presented and the outcomes regarding the evaluation
of the local borehole thermal resistance are discussed and compared with those from an erlier heat injection test performed in the same borehole.