Published June 23, 2014
| Version v1
Conference paper
Link calibration against receiver calibration time transfer uncertainty when using the Global Positioning System
Contributors
Others:
- Systèmes de Référence Temps Espace (SYRTE) ; Université Pierre et Marie Curie - Paris 6 (UPMC)-Institut national des sciences de l'Univers (INSU - CNRS)-Observatoire de Paris ; Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)
- Références micro-ondes et échelles de temps ; Systèmes de Référence Temps Espace (SYRTE) ; Institut national des sciences de l'Univers (INSU - CNRS)-Observatoire de Paris ; Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Sorbonne Université (SU)-Centre National de la Recherche Scientifique (CNRS)-Institut national des sciences de l'Univers (INSU - CNRS)-Observatoire de Paris ; Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Sorbonne Université (SU)-Centre National de la Recherche Scientifique (CNRS)
- Géoazur (GEOAZUR 7329) ; Institut national des sciences de l'Univers (INSU - CNRS)-Observatoire de la Côte d'Azur ; COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Université Côte d'Azur (UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Université Côte d'Azur (UCA)-Centre National de la Recherche Scientifique (CNRS)-Institut de Recherche pour le Développement (IRD [France-Sud])
- NERC Space Geodetic Facility (SGF)
Description
We present a direct comparison between two different techniques for the relative calibration of time transfer between remote time scales when using the signals transmitted by the Global Positioning System (GPS). In the remote sites, the local measurements are driving either the computation of the hardware delays of the local GPS equipment with respect to a given reference GPS receiver, a receiver calibration, or the computation of a global hardware offset between two distribution reference points of the remote time scales, a link calibration. Both techniques do not require the same measurements on site, and we discuss the uncertainty budget computation differences. We report on one calibration campaign organized during Autumn 2013 between Observatoire de Paris (OP), Paris, France, Observatoire de la Côte dAzur (OCA), Plateau de Calern, France, and NERC Space Geodesy Facility (SGF), Herstmonceux, United Kingdom. We show the different ways to compute uncertainty budgets, leading to improvement factors of 1.2 to 1.5 on the hardware delay uncertainties when comparing the relative link calibration to the relative receiver calibration.
Abstract
International audienceAdditional details
Identifiers
- URL
- https://hal.archives-ouvertes.fr/hal-03743808
- URN
- urn:oai:HAL:hal-03743808v1
Origin repository
- Origin repository
- UNICA