We examine the sensitivity of a large scale two-phase liquid argon detector to the directionality of the dark matter signal. This study was performed under the assumption that, above 50 keV of recoil energy, one can determine (with some resolution) the direction of the recoil nucleus without head-tail discrimination, as suggested by past...
-
2019 (v1)PublicationUploaded on: April 14, 2023
-
2017 (v1)Publication
The DarkSide project at Laboratori Nazionali del Gran Sasso (LNGS) is a dark matter direct search experiment based on the detection of rare nuclear recoils possibly induced by hypothetical dark matter particles, which are supposed to be neutral, massive (> 10 GeV) and weakly interact- ing (WIMP). DarkSide aims to perform background-free WIMP...
Uploaded on: April 14, 2023 -
2015 (v1)Publication
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4±0.7)kg...
Uploaded on: October 11, 2023 -
2015 (v1)Publication
The DarkSide experiment is designed for the direct detection of Dark Matter with a double phase liquid Argon TPC operating underground at Laboratori Nazionali del Gran Sasso. The TPC is placed inside a 30 tons liquid organic scintillator sphere, acting as a neutron veto, which is in turn installed inside a 1 kt water Cherenkov detector. The...
Uploaded on: April 14, 2023 -
2017 (v1)Publication
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power...
Uploaded on: March 27, 2023 -
2023 (v1)Publication
No description
Uploaded on: February 11, 2024 -
2024 (v1)Publication
No description
Uploaded on: September 3, 2024 -
2019 (v1)Publication
We report measurements of the charged daughter fraction of 218Po as a result of the 222Rn alpha decay, and the mobility of 218Po+ ions, using radon-polonium coincidences from the 238U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of 218Po that is charged is found to be 0.37 ± 0.03 and the mobility of 218Po+ is...
Uploaded on: April 14, 2023 -
2018 (v1)Publication
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics 39Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the...
Uploaded on: April 14, 2023 -
2017 (v1)Publication
The DarkSide experiment aims to perform a background-free direct search for dark matter with a dual-phase argon TPC. The current phase of the experiment, DarkSide-50, is acquiring data at Laboratori Nazionali del Gran Sasso and produced the most sensitive limit on the WIMP-nucleon cross section ever obtained with a liquid argon target (2.0 ×...
Uploaded on: April 14, 2023 -
2016 (v1)Publication
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using a two-phase...
Uploaded on: April 14, 2023 -
2017 (v1)Publication
This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time...
Uploaded on: April 14, 2023 -
2016 (v1)Publication
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors...
Uploaded on: March 27, 2023 -
2017 (v1)Publication
DarkSide is a multi-stage program devoted to direct searches of Dark Matter particles with detectors based on double phase liquid Argon Time Projection Chamber. The DarkSide-50 setup is running underground at the Laboratori Nazionali del Gran Sasso. First it was operated with Atmospheric Argon and during that run (1422 ± 67) kg×d of truly...
Uploaded on: April 14, 2023 -
2018 (v1)Publication
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16 660±270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter...
Uploaded on: April 14, 2023 -
2017 (v1)Publication
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the...
Uploaded on: April 14, 2023 -
2018 (v1)Publication
We present the results of a search for dark matter weakly interacting massive particles (WIMPs) in the mass range below 20 GeV=c2 using a target of low-radioactivity argon with a 6786.0 kg d exposure. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso. The analysis is based on the ionization signal,...
Uploaded on: April 14, 2023